Winer Observatory Engineering UPS Status

2018.04.22 08:29:41 UT

ParameterNow-1 min.-2 min.-3 min.-4 min.
V In (Volts) 243.00 243.00 243.00 244.00 243.00
Frequency (Hz) 59.97 60.20 59.86 59.97 60.23
Mode Auto Auto Auto Auto Auto
Watts (W) 96 101 101 94 103
Ready Yes Yes Yes Yes Yes
VA Out (VA) 86 110 110 110 110
Inverter Off Off Off Off Off
V Out (V) 123.00 123.00 123.00 123.00 123.00
PF 1.00 1.00 1.00 1.00 1.00
Charger Off Off Off Off Off
I Out 0.90 0.90 0.90 0.90 0.90
Load (PerCent) 2% 2% 2% 2% 2%
Beeper Enabled Enabled Enabled Enabled Enabled
Run Time (Minutes) 720m 720m 720m 720m 720m
Level none none none none none
Voltage Battery (V) 52.68 52.68 52.68 52.62 52.68
Ambient Temperature (C) 29c 29c 29c 29c 29c
Tap Buck Buck Buck Buck Buck
I Battery 0.00 0.00 0.00 0.00 0.00
Brown Level (V) 148.00 148.00 148.00 148.00 148.00
Validity 2 2 2 2 2

UPS Message(s)

Sun Apr 22 01:28:20 2018

>>Read Time: +2458230.8530092593282461
status
Status report for FE7.0KVA [EA453FK007] (EA453FK007)
Thursday, November 16, 2017 - 06:27:02

Parameters System
---------------------------------- ----------------
V In 243.0 Freq 59.97 Mode: Auto
Watts 96 Ready: Yes
------------- VA Out 86 Inverter: Off
V Out 123.0 PF 1.00 ---- Charger: Off
I Out 0.9 Load 2% Beeper: Enabled
------------- RunTime 720m Level: (none)
V Batt 52.68 Amb Temp 29c Tap: Buck
I Batt 0.0 BrnLvl 148.0

Active Alarms
----------------------------------------------------------

Sun Apr 22 01:26:58 2018

>>Read Time: +2458230.8520601852796972
status
Status report for FE7.0KVA [EA453FK007] (EA453FK007)
Thursday, November 16, 2017 - 06:25:41

Parameters System
---------------------------------- ----------------
V In 243.0 Freq 60.20 Mode: Auto
Watts 101 Ready: Yes
------------- VA Out 110 Inverter: Off
V Out 123.0 PF 1.00 ---- Charger: Off
I Out 0.9 Load 2% Beeper: Enabled
------------- RunTime 720m Level: (none)
V Batt 52.68 Amb Temp 29c Tap: Buck
I Batt 0.0 BrnLvl 148.0

Active Alarms
----------------------------------------------------------

Sun Apr 22 01:25:37 2018

>>Read Time: +2458230.8511226852424443
status
Status report for FE7.0KVA [EA453FK007] (EA453FK007)
Thursday, November 16, 2017 - 06:24:19

Parameters System
---------------------------------- ----------------
V In 243.0 Freq 59.86 Mode: Auto
Watts 101 Ready: Yes
------------- VA Out 110 Inverter: Off
V Out 123.0 PF 1.00 ---- Charger: Off
I Out 0.9 Load 2% Beeper: Enabled
------------- RunTime 720m Level: (none)
V Batt 52.68 Amb Temp 29c Tap: Buck
I Batt 0.0 BrnLvl 148.0

Active Alarms
----------------------------------------------------------

Sun Apr 22 01:24:15 2018

>>Read Time: +2458230.8501736111938953
status
Status report for FE7.0KVA [EA453FK007] (EA453FK007)
Thursday, November 16, 2017 - 06:22:58

Parameters System
---------------------------------- ----------------
V In 244.0 Freq 59.97 Mode: Auto
Watts 94 Ready: Yes
------------- VA Out 110 Inverter: Off
V Out 123.0 PF 1.00 ---- Charger: Off
I Out 0.9 Load 2% Beeper: Enabled
------------- RunTime 720m Level: (none)
V Batt 52.62 Amb Temp 29c Tap: Buck
I Batt 0.0 BrnLvl 148.0

Active Alarms
----------------------------------------------------------

Sun Apr 22 01:22:53 2018

>>Read Time: +2458230.8492245371453464
status
Status report for FE7.0KVA [EA453FK007] (EA453FK007)
Thursday, November 16, 2017 - 06:21:36

Parameters System
---------------------------------- ----------------
V In 243.0 Freq 60.23 Mode: Auto
Watts 103 Ready: Yes
------------- VA Out 110 Inverter: Off
V Out 123.0 PF 1.00 ---- Charger: Off
I Out 0.9 Load 2% Beeper: Enabled
------------- RunTime 720m Level: (none)
V Batt 52.68 Amb Temp 29c Tap: Buck
I Batt 0.0 BrnLvl 148.0

Active Alarms
----------------------------------------------------------

Other Information

Normal UPS Page

Time of Last Reboot: 70 Days, 02h:28m:00s. Version: obsd, v2.1.7 09-February-2018 (P. N. Daly)

Template page last updated on: January 15, 2017